Photovoltaic Test Instruments ↗ NEW

NOVA PV

The sun generates. You verify.

From protective-conductor continuity to string insulation. NOVA PV brings together electrical measurements for commissioning and maintaining photovoltaic installations, with results you can save and transfer to a PC.

NOVA PV front view on a black background
1000 V DCVoc measurement range
15 AIsc short-circuit current
250 / 500 / 1000 VInsulation test voltages

NOVA PV / UNIKS

From modules to reports. Every test, organised.

Designed for installers and maintenance teams working on residential and commercial PV installations. The manual describes electrical tests according to EN 62446, on systems below 1000 V DC and within the instrument’s current limits.

NOVA PV in the field among photovoltaic panels

01 / CONTINUITY · RPE

Verify the protective earth connection.

Measure the low resistance of protective conductors and equipotential bonding. Low Ω mode tests both polarities and displays the higher value; R+ and R− allow separate tests. ZERO compensates for test-lead resistance, while an adjustable threshold provides a clear result.

NOVA PV three-quarter view on a black background

02 / INSULATION · RISO

Three voltages. Two test methods.

Select 250, 500 or 1000 V DC. Method 1 measures between two parts and also supports continuous testing. Method 2 measures between the joined positive and negative PV poles and PE, for modules and strings; continuous testing is not available in this mode. The display shows resistance, test voltage and the test outcome.

NOVA PV beside a photovoltaic inverter

03 / POLARITY · VOC · ISC

Conditions change. Keep comparisons clear.

The automatic sequence checks polarity, open-circuit voltage Voc and short-circuit current Isc. Simple mode displays the actual test readings. In manual mode, enter irradiance, temperature, module data and string configuration: NOVA PV calculates STC correction. Remote mode receives irradiance and temperature from a compatible meter over a wireless connection.

NOVA PV during work on a photovoltaic installation

04 / MEMORY · USB · REPORTS

Turn measurements into documentation.

Organise results by client, location, array, string and module. Transfer them via USB to the PC software described in the manual and generate editable Excel sheets: a results table or a test-certificate layout. Connection diagrams available through the help key support work on the instrument.

NOVA PV rear view

NOVA PV / Technical specifications

Technical specifications.

Values from the NOVA PV Italian manual V1.0. Accuracy is expressed as ± (% of reading + digits). Ranges and conditions depend on the selected function.

FunctionMeasurement rangeResolutionAccuracy / conditions
RPE continuity0.20–19.99 Ω 20.0–200.0 Ω0.01 Ω 0.1 Ω± (2% + 5 digits) ± (2% + 5 digits)Test current ≥ 200 mA (≤ 2 Ω + Rc); test voltage 4–24 V DC.
Open-circuit voltage Voc5.0–99.9 V 100–1000 V0.1 V 1 V± (1% + 2 digits)Polarity check included.
Short-circuit current Isc0.2–15.0 A0.1 A± (1% + 2 digits)Condition: Voc > 20 V.
Insulation · method 1 · 250 V0.20–19.99 MΩ 20–99.9 MΩ0.01 MΩ 0.1 MΩ± (5% + 5 digits) ± (10% + 5 digits)Test voltage: +20% / −0%.
Insulation · method 1 · 500/1000 V0.20–19.99 MΩ 20.0–99.9 MΩ 100–300 MΩ0.01 MΩ 0.1 MΩ 1 MΩ± (5% + 5 digits) ± (10% + 5 digits) ± (20% + 5 digits)Test voltage: +20% / −0%.
Insulation · method 2 · 250/500/1000 V0.2–19.9 MΩ0.1 MΩ± (5% + 5 digits)Test voltage: +20% / −0%.
AC TRMS voltage5.0–99.9 V 100–700 V0.1 V 1 V± (5% + 2 digits)AC frequency: 50–60 Hz.
DC voltage5.0–99.9 V 100–1000 V0.1 V 1 V± (5% + 2 digits)

The Voc range reaches 1000 V; the manual specifies use on systems below 1000 V DC. Also observe the 15 A Isc limit and all connection and test conditions in the manual.